Close Go back Collapse all sections
Process Data set: Damp insulation PA; PA (en) en de

A superceding data set exists.

View superceding data set

Key Data Set Information
Location DE
Geographical representativeness description The data set represents the country specific situation in Germany, focusing on the main technologies, the region specific characteristics and / or import statistics.
Reference year 2022
Name
Base name ; Quantitative product or process properties
Damp insulation PA; PA
Use advice for data set The data set represents a cradle to gate inventory. It can be used to characterise the supply chain situation of the respective commodity in a representative manner. Combination with individual unit processes using this commodity enables the generation of user-specific (product) LCAs.
Technical purpose of product or process This product can be used in construction.
Classification number 6.6.02
Classification
Class name : Hierarchy level
  • oekobau.dat: 6.6.02 Plastics / Foils and fleeces / Vapour barriers and brakes
General comment on data set This data set has been modeled according to the European Standard EN 15804+A2 for Sustainable Building. Results are depicted in modules that allow the structured expression of results over the entire life cycle.
Uncertainty margins 20
Description Product system depicted except for a few missing processes / flows. Technological, temporal and geographic representativeness partly given.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Material properties of the reference flow
    • grammage: 0.08 kg/m^2
Biogenic carbon content
  • Biogenic carbon content in product (Biog. C in product): 0.0 kg
  • Biogenic carbon content in accompanying packaging (Biog. C in packaging): 0.0 kg
Time representativeness
Data set valid until 2024
Time representativeness description Annual average
Technological representativeness
Technology description including background system The LCA of the vapour barrier covers the cradle-to-gate phase. The system boundaries are represented by the finished product. 10% of antimony trioxide has been used as flame retardant. Transports from the factory to the point of installation are not considered and must be included according to the system boundaries. Production of PA 6: Nylon 6 is produced from caprolactam which is synthesized from benzene, ammonia, hydrogen and sulphuric acid (oleum). Via the intermediate products cyclohexane and cyclohexanone, the monomer caprolactam is produced. The Nylon 6 is produced by the reaction of caprolactam with water over producing the intermediate product aminocaproic acid. The acid is formed by ring- opening of caprolactam when water is added. Caprolactam and water are therefore heated to 250°C. Nylon 6 is then formed by the copolymerization of caprolactam and aminocaproic acid. The process can be carried out batchwise or continuously. In module C1, a manual dismantling (no loads) is assumed, collecting losses are neglected. The transport in module C2 to the recycling plant takes place with a truck (50km). Module C3 takes into account the grinding and thermal treatment (combustion) of the material. When calculating combustion emissions and credits, the specific calorific value of each material and the material composition are taken into account. In module D credits for the substitution of electricity (German electricity mix) and thermal energy (from natural gas) are given.
Flow diagram(s) or picture(s)
  • construction_de_damp insulation pa.jpg Image

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
C2
Waste processing
C3
Recycling Potential
D
Input
  • 0.8833
  • 0.0002473
  • 0.01936
  • -0.406
Input
  • 0
  • 0
  • 0
  • 0
Input
  • 0.8833
  • 0.0002473
  • 0.01936
  • -0.406
Input
  • 8.615
  • 0.003827
  • 3.188
  • -0.9441
Input
  • 2.56
  • 0
  • -2.56
  • 0
Input
  • 11.17
  • 0.003827
  • 0.6284
  • -0.9441
Input
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
Input
  • 0.001661
  • 2.252E-7
  • 0.0005321
  • -0.0001397
Output
  • 9.733E-10
  • 1.025E-14
  • 1.499E-11
  • -3.282E-11
Output
  • 0.01118
  • 5.58E-7
  • 0.001132
  • -0.0005368
Output
  • 0.0001536
  • 4.002E-9
  • 0.000001996
  • -0.00004036
Output
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.08
  • 0
Output
  • 0
  • 0
  • 0.3015
  • 0
Output
  • 0
  • 0
  • 0.5722
  • 0

IndicatorUnit Production
A1-A3
Transport
C2
Waste processing
C3
Recycling Potential
D
  • 0.5712
  • 0.0002841
  • 0.2195
  • -0.06254
  • 0.001996
  • -8.654E-7
  • 0.00003182
  • -0.0006822
  • 0.5692
  • 0.0002833
  • 0.2195
  • -0.06186
  • 0.00006471
  • 0.000001686
  • 6.347E-7
  • -0.000005798
  • 1.669E-12
  • 4.936E-17
  • 3.946E-14
  • -8.636E-13
  • 0.0009792
  • 7.624E-7
  • 0.000543
  • -0.00006008
  • 0.002832
  • 8.436E-7
  • 0.0004241
  • -0.00006463
  • 0.002169
  • 0.000004383
  • 0.002402
  • -0.0002485
  • 8.362E-7
  • 6.572E-10
  • 1.15E-8
  • -1.723E-7
  • 0.0002663
  • 3.9E-7
  • 0.0002133
  • -0.00002342
  • 0.03772
  • 0.000001467
  • 0.02251
  • -0.0008624
  • 0.002879
  • 1.998E-11
  • 3.242E-10
  • -5.791E-9
  • 11.66
  • 0.003825
  • 0.1163
  • -0.9439
  • 0.2463
  • 0.00003082
  • 0.001045
  • -0.04529
  • 0.02881
  • 0.00007205
  • 0.00147
  • -0.002317
  • 0.04975
  • 0.0005937
  • 0.004571
  • -0.005933
  • 0.004492
  • 0.000001343
  • 0.0000181
  • -0.00235
  • 0
  • 0
  • 0
  • -0.000001545
  • 0
  • 0
  • 0
  • 0
  • 0.2602
  • 0.00003769
  • 0.001168
  • -0.05156
  • 0.07101
  • 0.0001373
  • 0.001893
  • -0.00714
  • 0.05138
  • 0.0006035
  • 0.004812
  • -0.006078
  • 0.005169
  • 0.000001544
  • 0.00002082
  • -0.002703
  • 0
  • 0
  • 0
  • -0.000001935
  • 0
  • 0
  • 0
  • 0