Tags | Dieser Datensatz ist Bestandteil der ÖKOBAUDAT. |
Key Data Set Information | |||
Location | RER | ||
Reference year | 2022 | ||
Name |
| ||
Use advice for data set | Scope: The insulation materials Therma™ TR26 and Therma™ TT46 are produced by Kingspan Insulation at the manufacturing facilities in Winterswijk (the Netherlands), Burkhardtsdorf (Germany) and Kankaanpää (Finland). This EPD is based on weighted averages which have been determined on the basis of the single values originating from the different Kingspan Insulation factories. Therma™ TR26 Roof Board is an insulation board with a rigid thermoset polyisocyanurate (PIR) fibre free insulation core, faced on both sides with a low emissivity composite foil. Therma™ TR26 Roof Board is used as thermal insulation under mechanically fixed or non-fixed ballasted roofing systems. Therma™ TT46 Tapered Roof Board is an insulation board with a rigid thermoset PIR fibre free insulation core, faced on both sides with a low emissivity composite foil. Therma™ TT46 Tapered Roof Board is used as thermal insulation under mechanically fixed or non-fixed ballasted roofing systems and enhances water drainage from flat roofs. In order to enable the user of the EPD to calculate the LCA results for different thicknesses, the EPD contains the respective calculation rules. System boundary: The type of EPD according to EN 15804 is: cradle to gate with options, modules C1–C4, and module D (A1–A3, C, D and additional modules: A4, A5). The product stage is a mandatory information module and it covers: · A1, raw material extraction and processing, processing of secondary material input (e.g. recycling processes), · A2, transport to the manufacturer, · A3, manufacturing, including provision of all materials, products and energy, packaging processing and its transport, as well as waste processing up to the end-of-waste state or disposal of final residues during the product stage. The construction process stage includes: · A4 transport to the building site; · A5 installation in the building including provision of all materials, products and energy, as well as waste processing up to the end-of waste state or disposal of final residues during the construction process stage. The end-of-life stage is a mandatory information module and it covers: · C1 de-construction, demolition; · C2 transport to waste processing; · C3 waste processing for reuse, recovery and/or recycling; · C4 disposal (not applicable for this EPD) including provision and all transport, provision of all materials, products and related energy and water use. Environmental burden of the incineration (R1 > 60 %) of the product at the end-of-life stage are assigned to the product system (C3); resulting potential credits for thermal and electrical energy from energy substitution are declared in module D. | ||
Technical purpose of product or process | Therma™ TR26 Roof Board is used as thermal insulation under mechanically fixed or non-fixed ballasted roofing systems. Therma™ TT46 Tapered Roof Board is used as thermal insulation under mechanically fixed or non-fixed ballasted roofing systems and enhances water drainage from flat roofs. | ||
Classification number | 2.4.01 | ||
Classification |
Class name
:
Hierarchy level
| ||
General comment on data set | Therma™ TR26 and Therma™ TT46 Roof Boards are insulation boards with a rigid thermoset polyisocyanurate (PIR) fibre free insulation core, faced on both sides with a low emissivity composite foil. The products are available in variable thicknesses from 20 mm up to 200 mm. This EPD is based on a thickness of 120 mm and RD-value of 5,45 m²·K/W. | ||
Copyright | Yes | ||
Owner of data set | |||
Quantitative reference | |||
Reference flow(s) |
| ||
Time representativeness | |||
Data set valid until | 2027 | ||
Technological representativeness | |||
Technology description including background system | Kingspan Therma is made through a manufacturing process in which a foam forms an insulating core between two facing elements. At the start of the process a mix of chemicals is added directly to the bottom layer of facing and then expands to meet the top layer of facing. As it dries, the foam becomes tacky and adheres itself to the facing, top and bottom. Once it has reached the necessary thickness the foam is cooked under pressure. The insulation boards are then cut into the necessary sizes, packaged and sent to the loading bay for collection. Declared unit: The declared unit (1 m²) and conversion factors are listed in the table below. |
Subtype | average dataset | ||||
LCA methodology report | |||||
Data sources, treatment and representativeness | |||||
Documentation of data quality management | |||||
Data source(s) used for this data set | |||||
Completeness | |||||
Validation | |||||
| |||||
Compliance Declarations |
Compliance |
Compliance system name
|
Approval of overall compliance
|
Nomenclature compliance
|
Methodological compliance
|
Review compliance
|
Documentation compliance
|
Quality compliance
|
Compliance |
Compliance system name
|
Approval of overall compliance
|
Nomenclature compliance
|
Methodological compliance
|
Review compliance
|
Documentation compliance
|
Quality compliance
|
Commissioner and goal | |
Commissioner of data set | |
Data generator | |
Data set generator / modeller | |
Data entry by | |
Time stamp (last saved) | 2022-11-25T09:51:57.495 |
Data set format(s) | |
Publication and ownership | |
UUID | a23d27be-50e8-47ea-b74c-34e46efd2f44 |
Data set version | 00.01.000 |
Registration authority | |
Registration number | EPD-KSI-20220298-LT1-EN |
Owner of data set | |
Copyright | Yes |
License type | Free of charge for all users and uses |
Access and use restrictions | None |
Indicators of life cycle