Close Go back Collapse all sections
Process Data set: DuPont™ AirGuard® Air & Vapour Control Layers (5816X) (en) en de

Tags Dieser Datensatz ist Bestandteil der ÖKOBAUDAT.
Key Data Set Information
Location LU
Reference year 2022
Name
DuPont™ AirGuard® Air & Vapour Control Layers (5816X)
Use advice for data set Scope: This document applies to DuPont™ AirGuard® Air & Vapour Control Layer 5816X, made of glass fibre, aluminium and adhesive. The declared unit weight is 171.5 g/m2. LCA data were compiled using production data for the year 2021, as well as for the year 2019 for the finishing processing (used for EPDs of Tyvek® products published in 2021). The declaration holder is responsible for the underlying data and its verification. System boundary: Type of EPD: Cradle-to-gate (with options) The system boundaries of the EPD follow the modular construction system as described by EN 15804. The LCA considers the following modules: · A1-A3: Manufacturing of pre-products, packaging, ancillary materials, transport to the factory and production, with the associated energy supply and waste handling · A4: Transport to the construction site · A5: Installation into the building including disposal of packaging · C4: Waste disposal, namely incineration · D: Potential for reuse, recovery and/or recycling including benefits for product incineration from module C4
Technical purpose of product or process This product is used on the warm side of the building envelope. It will provide a barrier to water vapour and air movement. Additional features: • Fire-retardant. Reaction to fire: A2-s1, d0 to EN 13501-1: 2007+A1:2009 • AirGuard® A2 FR AVCL and DuPont™ AirGuard® FR System tape is tested and classified for free-span, on mineral wool slab, gypsum plasterboard or fibre cement board • Suitable for all building types, heights and proximities • High vapour resistance, limiting interstitial condensation • Suitable for high humidity buildings, such as swimming pool halls etc • Thermal benefit in combination with a cavity due to the low emissivity/reflective surface
Classification number 6.6.02
Classification
Class name : Hierarchy level
  • OEKOBAU.DAT: 6.6.02 Plastics / Foils and fleeces / Vapour barriers and brakes
  • IBUCategories: null / null / null
General comment on data set DuPont™ AirGuard® A2 FR AVCL is a fire-retardant airtight vapour control layer for use within the internal lining of roof, ceiling and wall systems. Enhancing the building fabric in terms of airtightness, energy efficiency and moisture management, improving indoor air quality and providing exceptional fire safety to the building and its occupants.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Material properties of the reference flow
    • layer thickness: 1.5E-4 m
    • grammage: 0.1715 kg/m^2
Time representativeness
Data set valid until 2027
Technological representativeness
Technology description including background system DuPont™ AirGuard® A2FR AVCL (Style 5816X) is an air barrier and vapour control layer with a low-emissivity aluminium foil face on one side. It is placed on the warm side of the insulation with the foil surface facing the interior of the building. It has Water vapour transmission (sd) 2000m, a Reflective surface with e = 0.05 and superior mechanical strength. In addition, it has reaction to fire class A2 and will contribute to the safety of any building envelope. Declared unit: This declaration applies to 1 m2 of DuPont™ AirGuard® Air & Vapour Control Layer 5816X, with a declared unit weight of 171.5 g/m2.

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
Disposal
C4
Recycling Potential
D
Input
  • 6.119
  • 0.01241
  • 0.0001034
  • 0.002698
  • -0.9081
Input
  • 0.0003358
  • 6.834E-14
  • 6.326E-15
  • 0.000003196
  • -6.898E-11
Input
  • 6.119
  • 0.01241
  • 0.0001034
  • 0.002701
  • -0.9081
Input
  • 15.81
  • 0.2244
  • 0.0008118
  • 0.1058
  • -5.356
Input
  • 0.0003319
  • 0.000007673
  • 1.744E-8
  • 3.072E-10
  • -0.0001254
Input
  • 15.81
  • 0.2244
  • 0.0008118
  • 0.1058
  • -5.356
Input
  • 0.00486
  • 0
  • 0
  • 0
  • 0
Input
  • 5.652E-8
  • 0
  • 0
  • 0
  • 0
Input
  • 6.229E-7
  • 0
  • 0
  • 0
  • 0
Input
  • 0.01489
  • 0.00001405
  • 0.000001497
  • 0
  • -0.0008769
Output
  • 2.242E-9
  • 1.07E-12
  • 1.029E-13
  • 0
  • -8.233E-10
Output
  • 0.2635
  • 0.00003187
  • 0.0004085
  • 0
  • -0.00214
Output
  • 0.0008599
  • 2.759E-7
  • 1.511E-8
  • 0
  • -0.0002582
Output
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0.00138
  • 0.905
Output
  • 0
  • 0
  • 0
  • 0.00249
  • 2.98

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Disposal
C4
Recycling Potential
D
  • 1.179
  • 0.01685
  • 0.001927
  • 0.5533
  • -0.3237
  • 0.01408
  • 0.0002678
  • 0.001771
  • -0.00003276
  • -0.001221
  • 1.165
  • 0.01649
  • 0.0001562
  • 0.5534
  • -0.3225
  • 0.0005325
  • 0.00009094
  • 2.322E-8
  • 0
  • -0.00002428
  • 6.717E-12
  • 1.005E-15
  • 1.466E-16
  • 3.644E-10
  • -1.312E-12
  • 0.002932
  • 0.0001034
  • 6.67E-7
  • 0.00003645
  • -0.0002851
  • 0.005985
  • 0.0001151
  • 4.003E-7
  • 0.00007287
  • -0.0003264
  • 0.01042
  • 0.0005799
  • 0.000001647
  • 0.0002909
  • -0.001083
  • 0.000001212
  • 4.879E-8
  • 3.347E-9
  • 1.324E-9
  • -2.745E-7
  • 0.0009539
  • 0.00005244
  • 1.704E-7
  • 0.00001245
  • -0.0001
  • 0.2348
  • 0.0001472
  • 0.0001052
  • 0.04861
  • -0.02063
  • 1.354E-7
  • 1.381E-9
  • 5.051E-12
  • 7.781E-15
  • -3.529E-8
  • 15.79
  • 0.2239
  • 0.0008114
  • 0.1058
  • -5.355

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Comparative toxic unit for humans (carcinogenic) (HTP-c) 2
  • ND
  • ND
  • ND
  • ND
  • ND
Comparative toxic unit for humans (noncarcinogenic) (HTP-nc) 2
  • ND
  • ND
  • ND
  • ND
  • ND
Incidence of disease due to PM emissions (PM) 2
  • ND
  • ND
  • ND
  • ND
  • ND
Human exposure efficiency relative to U235 (IR) 1
  • ND
  • ND
  • ND
  • ND
  • ND
Comparative toxic unit for ecosystems (ETP-fw) 2
  • ND
  • ND
  • ND
  • ND
  • ND
Soil quality index (SQP) 2
  • ND
  • ND
  • ND
  • ND
  • ND