Tags | Dieser Datensatz ist Bestandteil der ÖKOBAUDAT. |
Key Data Set Information | |||
Location | RER | ||
Reference year | 2021 | ||
Name |
| ||
Use advice for data set | Scope: The insulation material Kooltherm® is produced by Kingspan Insulation B.V. at the manufacturing facility in Tiel, the Netherlands. A glass tissue based facing is autohesively bonded to the insulation core during manufacture. In order to enable the user of the EPD to calculate the LCA results for different thicknesses, the EPD contains the respective calculation rules. System boundary: Type of EPD: according to EN 15804: cradle to gate with options, modules C1–C4, and module D (A1–A3, C, D and additional modules: A4,A5). According to PCR Part A: 1a) declaration of one specific product from one plant of one manufacturer. The product stage is a mandatory information module and it covers: - A1, raw material extraction and processing, processing of secondary material input (e.g. recycling processes) - A2, transport to the manufacturer - A3, manufacturing, including the provision of all materials, products and energy, packaging processing and its transport, as well as waste processing up to the end-of waste state or disposal of final residues during the product stage. The construction process stage includes: - A4 transport to the building site; - A5 installation in the building including provision of all materials, products and energy, as well as waste processing up to the end-of-waste state or disposal of final residues during the construction process stage. The end-of-life stage is a mandatory information module and it covers: - C1 de-construction, demolition; - C2 transport to waste processing; - C3 waste processing for reuse, recovery and/or recycling; - C4 disposal (not applicable for this EPD) including provision and all transport, provision of all materials, products and related energy and water use. Environmental burden of the incineration (R1 > 60%) of the product at the end-of-life stage are assigned to the product system (C3); resulting potential credits for thermal and electrical energy from energy substitution are declared in module D. Renewable electricity sources for manufacturing All electricity used during production comes from renewable sources. By generating energy on-site with solar panels and with procured energy from fully certified renewable sources. Following the global Net Zero Energy strategy from Kingspan Group plc. | ||
Technical purpose of product or process | Due to its high insulating value the Kooltherm® K15 C is suitable for use as insulation for ventilated facades in both new and renovation construction and also on concrete element in semi-sandwich constructions. | ||
Classification number | 2.5.01 | ||
Classification |
Class name
:
Hierarchy level
| ||
General comment on data set | The Kooltherm® K15 C is a rigid thermoset cellular insulation material faced on one side with microperforated aliminum based facing, and on other side with a mineral based glass tisue. The product is available in variable thicknesses from 20 mm up to 200 mm. This EPD covers one of the most commonly sold thickness of 100 mm with an RD-value of 5,0 m² K/W. | ||
Copyright | Yes | ||
Owner of data set | |||
Quantitative reference | |||
Reference flow(s) |
| ||
Time representativeness | |||
Data set valid until | 2026 | ||
Technological representativeness | |||
Technology description including background system | Phenolic foam is produced by the use of phenolic resin, a catalyst, additives and blowing agent. The cell structure is formed in the resin under the influence of heat released during the chemical reaction. Hereby, the blowing agent is incorporated into the material which forms a solid and very fine cell structure, which is nearly 100% closed. The foam is applied on the facings. After this, the thickness and strength is determined by the conveyor belt where upper and lower rollers compress the material into the desired thickness. The board is sawed into the correct size and packed according to the product specification. Declared unit: The declared unit (1 m²) and conversion factors are listed in the table below. |
Subtype | specific dataset | ||||
LCA methodology report | |||||
Data sources, treatment and representativeness | |||||
Documentation of data quality management | |||||
Data source(s) used for this data set | |||||
Completeness | |||||
Validation | |||||
| |||||
Compliance Declarations |
Compliance |
Compliance system name
|
Approval of overall compliance
|
Nomenclature compliance
|
Methodological compliance
|
Review compliance
|
Documentation compliance
|
Quality compliance
|
Compliance |
Compliance system name
|
Approval of overall compliance
|
Nomenclature compliance
|
Methodological compliance
|
Review compliance
|
Documentation compliance
|
Quality compliance
|
Commissioner and goal | |
Commissioner of data set | |
Data generator | |
Data set generator / modeller | |
Data entry by | |
Time stamp (last saved) | 2021-03-24T17:18:17.625 |
Data set format(s) | |
Publication and ownership | |
UUID | 2a7b2942-ff5d-4dca-8365-d4ffc28d013d |
Data set version | 00.02.000 |
Registration authority | |
Registration number | EPD-KSI-20200303-CBA1-EN |
Owner of data set | |
Copyright | Yes |
License type | Free of charge for all users and uses |
Access and use restrictions | None |
Indicators of life cycle