Close Go back Collapse all sections
Process Data set: Therma™ TR26 / Therma™ TT46 (en) en de

Tags Dieser Datensatz ist Bestandteil der ÖKOBAUDAT.
Key Data Set Information
Location RER
Reference year 2022
Name
Therma™ TR26 / Therma™ TT46
Use advice for data set Scope: The insulation materials Therma™ TR26 and Therma™ TT46 are produced by Kingspan Insulation at the manufacturing facilities in Winterswijk (the Netherlands), Burkhardtsdorf (Germany) and Kankaanpää (Finland). This EPD is based on weighted averages which have been determined on the basis of the single values originating from the different Kingspan Insulation factories. Therma™ TR26 Roof Board is an insulation board with a rigid thermoset polyisocyanurate (PIR) fibre free insulation core, faced on both sides with a low emissivity composite foil. Therma™ TR26 Roof Board is used as thermal insulation under mechanically fixed or non-fixed ballasted roofing systems. Therma™ TT46 Tapered Roof Board is an insulation board with a rigid thermoset PIR fibre free insulation core, faced on both sides with a low emissivity composite foil. Therma™ TT46 Tapered Roof Board is used as thermal insulation under mechanically fixed or non-fixed ballasted roofing systems and enhances water drainage from flat roofs. In order to enable the user of the EPD to calculate the LCA results for different thicknesses, the EPD contains the respective calculation rules. System boundary: The type of EPD according to EN 15804 is: cradle to gate with options, modules C1–C4, and module D (A1–A3, C, D and additional modules: A4, A5). The product stage is a mandatory information module and it covers: · A1, raw material extraction and processing, processing of secondary material input (e.g. recycling processes), · A2, transport to the manufacturer, · A3, manufacturing, including provision of all materials, products and energy, packaging processing and its transport, as well as waste processing up to the end-of-waste state or disposal of final residues during the product stage. The construction process stage includes: · A4 transport to the building site; · A5 installation in the building including provision of all materials, products and energy, as well as waste processing up to the end-of waste state or disposal of final residues during the construction process stage. The end-of-life stage is a mandatory information module and it covers: · C1 de-construction, demolition; · C2 transport to waste processing; · C3 waste processing for reuse, recovery and/or recycling; · C4 disposal (not applicable for this EPD) including provision and all transport, provision of all materials, products and related energy and water use. Environmental burden of the incineration (R1 > 60 %) of the product at the end-of-life stage are assigned to the product system (C3); resulting potential credits for thermal and electrical energy from energy substitution are declared in module D.
Technical purpose of product or process Therma™ TR26 Roof Board is used as thermal insulation under mechanically fixed or non-fixed ballasted roofing systems. Therma™ TT46 Tapered Roof Board is used as thermal insulation under mechanically fixed or non-fixed ballasted roofing systems and enhances water drainage from flat roofs.
Classification number 2.4.01
Classification
Class name : Hierarchy level
  • OEKOBAU.DAT: 2.4.01 Insulation materials / Polyurethane rigid foam / PU with aluminium
  • IBUCategories: null / null / null
General comment on data set Therma™ TR26 and Therma™ TT46 Roof Boards are insulation boards with a rigid thermoset polyisocyanurate (PIR) fibre free insulation core, faced on both sides with a low emissivity composite foil. The products are available in variable thicknesses from 20 mm up to 200 mm. This EPD is based on a thickness of 120 mm and RD-value of 5,45 m²·K/W.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Material properties of the reference flow
    • grammage: 3.6 kg/m^2
    • gross density: 30.0 kg/m^3
    • layer thickness: 0.12 m
Time representativeness
Data set valid until 2027
Technological representativeness
Technology description including background system Kingspan Therma is made through a manufacturing process in which a foam forms an insulating core between two facing elements. At the start of the process a mix of chemicals is added directly to the bottom layer of facing and then expands to meet the top layer of facing. As it dries, the foam becomes tacky and adheres itself to the facing, top and bottom. Once it has reached the necessary thickness the foam is cooked under pressure. The insulation boards are then cut into the necessary sizes, packaged and sent to the loading bay for collection. Declared unit: The declared unit (1 m²) and conversion factors are listed in the table below.

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 28.85
  • 0.0229
  • 0.02051
  • 0.0001177
  • 0.01145
  • 0.3542
  • 0
  • -15.23
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 28.85
  • 0.0229
  • 0.02051
  • 0.0001177
  • 0.01145
  • 0.3542
  • 0
  • -15.23
Input
  • 152.3
  • 0.4039
  • 3.7
  • 0.03124
  • 0.2019
  • 113.7
  • 0
  • -53.51
Input
  • 115.3
  • 0
  • -3.62
  • 0
  • 0
  • -111.7
  • 0
  • 0
Input
  • 267.6
  • 0.4039
  • 0.07991
  • 0.03124
  • 0.2019
  • 2.019
  • 0
  • -53.51
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.0719
  • 0.00002591
  • 0.0004873
  • 1.776E-7
  • 0.00001295
  • 0.01816
  • 0
  • -0.01644
Output
  • 1.12E-7
  • 1.934E-12
  • 6.655E-12
  • 1.032E-13
  • 9.67E-13
  • 2.763E-10
  • 0
  • -6.623E-9
Output
  • 0.2845
  • 0.00005788
  • 0.01944
  • 0.000002924
  • 0.00002894
  • 0.04369
  • 0
  • -0.08045
Output
  • 0.002936
  • 4.974E-7
  • 0.000003324
  • 3.424E-8
  • 2.487E-7
  • 0.00008402
  • 0
  • -0.004186
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0254
  • 0
  • 0
Output
  • 0
  • 0
  • 0.08662
  • 0
  • 0
  • 3.455
  • 0
  • 0
Output
  • 0
  • 0
  • 0.3928
  • 0
  • 0
  • 13.18
  • 0
  • 0
Output
  • 0
  • 0
  • 0.7029
  • 0
  • 0
  • 23.57
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
  • 10.1
  • 0.03026
  • 0.2164
  • 0.002307
  • 0.01513
  • 7.793
  • 0
  • -3.212
  • -0.2353
  • -0.00004164
  • 0.00001182
  • 0.000003083
  • -0.00002082
  • 0.1664
  • 0
  • -0.01589
  • 10.33
  • 0.03014
  • 0.2164
  • 0.002304
  • 0.01507
  • 7.627
  • 0
  • -3.195
  • 0.006698
  • 0.0001681
  • 0.000002566
  • 2.842E-8
  • 0.00008404
  • 0.00001429
  • 0
  • -0.0003649
  • 2.822E-11
  • 1.807E-15
  • 3.85E-14
  • 1.413E-16
  • 9.031E-16
  • 5.77E-13
  • 0
  • -2.053E-11
  • 0.02772
  • 0.00002737
  • 0.00002084
  • 0.00001446
  • 0.00001368
  • 0.005637
  • 0
  • -0.003355
  • 0.02177
  • 0.00003106
  • 0.00002696
  • 0.0000107
  • 0.00001553
  • 0.004545
  • 0
  • -0.004913
  • 0.05781
  • 0.0001209
  • 0.0001226
  • 0.00005582
  • 0.00006048
  • 0.02527
  • 0
  • -0.01272
  • 0.00004659
  • 8.999E-8
  • 9.725E-9
  • 4.647E-10
  • 4.499E-8
  • 1.562E-7
  • 0
  • -0.000004221
  • 0.0056
  • 0.00001017
  • 0.000007229
  • 0.000005097
  • 0.000005081
  • 0.002195
  • 0
  • -0.001185
  • 1.558
  • 0.0002704
  • 0.02052
  • 0.000004281
  • 0.0001352
  • 0.7722
  • 0
  • -0.3511
  • 0.00001139
  • 2.52E-9
  • 9.405E-10
  • 9.429E-11
  • 1.26E-9
  • 1.583E-8
  • 0
  • -4.676E-7
  • 267.5
  • 0.4029
  • 0.07986
  • 0.03116
  • 0.2014
  • 2.018
  • 0
  • -53.5

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Comparative toxic unit for humans (carcinogenic) (HTP-c) 2
  • 7.212E-9
  • 5.638E-12
  • 3.204E-12
  • 4.014E-13
  • 2.818E-12
  • 5.207E-11
  • 0
  • -6.297E-10
Comparative toxic unit for humans (noncarcinogenic) (HTP-nc) 2
  • 6.132E-7
  • 2.925E-10
  • 3.245E-10
  • 2.029E-11
  • 1.463E-10
  • 1.899E-9
  • 0
  • -2.216E-8
Incidence of disease due to PM emissions (PM) 2
  • 1.833E-7
  • 1.794E-10
  • 3.289E-10
  • 1.212E-10
  • 8.967E-11
  • 1.273E-8
  • 0
  • -4.274E-8
Human exposure efficiency relative to U235 (IR) 1
  • 0.3525
  • 0.00007289
  • 0.0004562
  • 0.000004984
  • 0.00003644
  • 0.01347
  • 0
  • -0.7148
Comparative toxic unit for ecosystems (ETP-fw) 2
  • 109.5
  • 0.2797
  • 0.05716
  • 0.0217
  • 0.1398
  • 0.6958
  • 0
  • -12.12
Soil quality index (SQP) 2
  • 64.29
  • 0.1386
  • 0.0204
  • 0.00008599
  • 0.06931
  • 0.4262
  • 0
  • -9.225