Process Data set: Use - 1 kWh of final energy from oil low temp. and calorific value (according to EnEV) (en) en de

Tags Dieser Datensatz ist Bestandteil der ÖKOBAUDAT.
Key Data Set Information
Location DE
Geographical representativeness description The data set represents the country specific situation in Germany, focusing on the main technologies, the region specific characteristics and / or import statistics.
Reference year 2018
Name
Use - 1 kWh of final energy from oil low temp. and calorific value (according to EnEV)
Use advice for data set This dataset refers to the production of 1 kWh of thermal energy from light fuel oil low-temperature or calorific value. The data set is intended for the use of final energy acc. EnEV as reference. The final energy acc. EnEV already takes into account system losses and system efficiency as well as power supply and power consumption, which is why this is not included in this data set. Therefore, the combustion process is calculated with 100% efficiency. To calculate the life cycle assessment results at building level, the indicator results have to be multiplied with the final energy demand acc. EnEV.
Technical purpose of product or process Thermal energy from light fuel oil is used for heating a building or technical processes (e.g. drying).
Classification number 8.6.06
Classification
Class name : Hierarchy level
  • oekobau.dat: 8.6.06 Building service engineering / Use / Use heat generator (EnEV)
General comment on data set This data set has been modeled according to the European Standard EN 15804 for Sustainable Building. Results are depicted in modules that allow the structured expression of results over the entire life cycle.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Time representativeness
Data set valid until 2022
Time representativeness description Annual average
Technological representativeness
Technology description including background system This dataset includes crude oil extraction, refinery processes, transportation and combustion. Since final energy gem. EnEV is provided as a reference, a boiler efficiency of 100% was modelled. Usually occurring system losses, as well as power supply and power consumption in relation to boiler operation are not included in this data set. The life cycle assessment is dominated by the combustion process.

Indicators of life cycle

IndicatorDirectionUnit Operational energy use
B6
Input
  • 0.0195
Input
  • 0
Input
  • 0.0195
Input
  • 4.192
Input
  • 0
Input
  • 4.192
Input
  • 0
Input
  • 0
Input
  • 0
Input
  • 0.00002145
Output
  • 4.875E-10
Output
  • 0.0005766
Output
  • 0.000003798
Output
  • 0
Output
  • 0
Output
  • 0
Output
  • 0
Output
  • 0

IndicatorUnit Operational energy use
B6
  • 0.2996
  • 9.669E-17
  • 0.00002755
  • 0.0001847
  • 0.0000268
  • 1.12E-8
  • 4.182