Close Go back Collapse all sections
Process Data set: Usage - tube collector (1m² and year), acc. EnEV; 1 m2 and year (en) en de

Tags Dieser Datensatz ist Bestandteil der ÖKOBAUDAT.
Key Data Set Information
Location DE
Geographical representativeness description The data set represents the country specific situation in Germany, focusing on the main technologies, the region specific characteristics and / or import statistics.
Reference year 2018
Name
Base name ; Quantitative product or process properties
Usage - tube collector (1m² and year), acc. EnEV; 1 m2 and year
Use advice for data set The data set represents a cradle to gate inventory. It can be used to characterise the supply chain situation of the respective commodity in a representative manner. Combination with individual unit processes using this commodity enables the generation of user-specific (product) LCAs.
Technical purpose of product or process This product can be used in construction.
Classification number 8.6.06
Classification
Class name : Hierarchy level
  • oekobau.dat: 8.6.06 Building service engineering / Use / Use heat generator (EnEV)
General comment on data set This data set has been modeled according to the European Standard EN 15804 for Sustainable Building. Results are depicted in modules that allow the structured expression of results over the entire life cycle.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Time representativeness
Data set valid until 2022
Time representativeness description Annual average
Technological representativeness
Technology description including background system The annual effective usable thermal energy for hot water producing by solar collectors per square meter collector surface was calculated according to DIN 18599 and suitable factors for flat collectors since 1998 were used. For Germany an average radiation intensity of 1200 kWh/(m2*a) was applied. The generated usable thermal energy amounts to 403 kWh per square meter solar collector surface. Background system: Electricity: Electricity is modelled according to the individual country-specific situations. The country-specific modelling is achieved on multiple levels. Firstly, individual energy carrier specific power plants and plants for renewable energy sources are modelled according to the current national electricity grid mix. Modelling the electricity consumption mix includes transmission / distribution losses and the own use by energy producers (own consumption of power plants and "other" own consumption e.g. due to pumped storage hydro power etc.), as well as imported electricity. Secondly, the national emission and efficiency standards of the power plants are modelled as well as the share of electricity plants and combined heat and power plants (CHP). Thirdly, the country-specific energy carrier supply (share of imports and / or domestic supply) including the country-specific energy carrier properties (e.g. element and energy content) are accounted for. Fourthly, the exploration, mining/production, processing and transport processes of the energy carrier supply chains are modelled according to the specific situation of each electricity producing country. The different production and processing techniques (emissions and efficiencies) in the different energy producing countries are considered, e.g. different crude oil production technologies or different flaring rates at the oil platforms.
Flow diagram(s) or picture(s)
  • construction_de_tube collector (big plant 500m2).jpg Image

Indicators of life cycle

IndicatorDirectionUnit Operational energy use
B6
Input
  • 4.32E+3
Input
  • 0
Input
  • 4.32E+3
Input
  • 0
Input
  • 0
Input
  • 0
Input
  • 0
Input
  • 0
Input
  • 0
Input
  • 0
Output
  • 0
Output
  • 0
Output
  • 0
Output
  • 0
Output
  • 0
Output
  • 0
Output
  • 0
Output
  • 0

IndicatorUnit Operational energy use
B6
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0